Sep 9, 2026
24 demerits
· 6 violations
#2 · Water quality: disinfectant residual provided by −6
Chlorine bleaching out test kit. G.S. 130A-2(3) Chlorine bleached out test kit. Imminent Hazard to public. Lower to measurable level. - Corrected.
#3 · Water quality: pool water pH −6
PH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.8.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent cyanuric acid or total alkalinity checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor dirty covered in layer of plaster dust. .2537(14) Keep pool surface and pool floor free of debris. - Corrected, CPO vacuumed pool.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light burned out in pump room. .2533(b) Provide sufficient lighting in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms 114.6F. .2526(i) Water in restrooms shall not exceed 110 F.
View this inspection on the county portal ›
May 1, 2023
14 demerits
· 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
Observed pH at 8.3. Corrected at 7.2
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed floating debris in pool. CDI
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed floating debris in skimmer. CDI
View this inspection on the county portal ›
Apr 14, 2022
6 demerits
· 3 violations
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed piping and valves in pump room in need of labeling, some labels have faded.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no airgap at backwash.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backblow preventer at exterior hose bib.
View this inspection on the county portal ›
Apr 28, 2021
10 demerits
· 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0. CDI - CPO corrected to 7.5
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Provide a 2” air gap at back wash
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Back flow preventer required on hose bib
View this inspection on the county portal ›
May 8, 2019
12 demerits
· 6 violations
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Floor wet, store bagged chemicals off floor, natural cross or continuous forced ventilation required, chemical room needs light
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Remark faded labels
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatter-resistant
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Back flow preventer required on hose bib
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Floors should be slip-resistant
View this inspection on the county portal ›
May 17, 2017
12 demerits
· 4 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC form does not match what is installed. Wading pool recently replastered, equalizer line cover plastered over and plugged inside the skimmer. Corrected PDSC form filled out by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan and light in chemical storage room not functioning. Provide functional light and ensure fan runs continuously.
#27 · Equipment room: filter backwash discharged through an air gap −2
Provide air gap for backwash.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Provide toilet paper in the restrooms.
View this inspection on the county portal ›