12demerits
NEXUS 485 APTS
2214 NEXUS DR, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530011
Latest result12 demerits
Last inspectedSep 28, 2026
Inspections on record5
On record sinceMar 27, 2025
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Mar 27, 2025Lower is betterSep 28, 2026
Inspections & violations
Sep 28, 2026 12 demerits · 3 violations
Inspector comments: POOL IS NOT APPROVED FOR NIGHT SWIMMING. POOL CANNOT BE OPEN AFTER DUSK OR BEFORE DAWN.
Permit Restriction: Pool pump flow must be at least 124gpm for turnover and cannot exceed 178gpm for skimmer line limitation. Flow meter must remain operational.
Observed the pool pump to have air in the basket chamber. The suction at the skimmers and the flow at the returns was very low to the point of being described as a faint feeling of flow. This motor and pump may not be functioning correctly. The flow meter was registering 0 GPM flow. Correct this issue. If the pump and/or motor is is replaced contact the Health Department to advised of the change as new paperwork will be required for submission to the main office and an electrical inspection with Charlotte-Mecklenburg Code enforcement will be required for any electrical work done. Because of this issue and because the CPO wished to shock the pool for maintenance, the CPO agreed to close the pool voluntarily at the end of the inspection. C. Elmore will follow up in 1-2 weeks to ensure that the pump system is corrected and that the water chemistry is correct.
CHLORINE CANNOT BE ADDED TO THE POOL BY HAND TO CORRECT LOW CHLORINE FOR OPERATION. CHLORINE MAY ONLY BE ADDED DIRECTLY TO THE POOL FOR SHOCK OR MAINTENANCE PURPOSES WHEN THE POOL IS CLOSED AND IS TO REMAIN CLOSED UNTIL THE SHOCK CHEMICALS HAVE SETTLED OUT AND THE POOL CHLORINE RESIDUAL IS BACK TO BEING MAINTAINED BY THE CHLORINE FEEDER SYSTEM.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable.
.2535(11) Provide weekly recordings for cyanuric acid and total alkalinity.
Observed gaps in the log book records. Keep the records properly for every day the pool is open. Most records were being kept properly.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed ring buoy throw rope to be the improper length due to being tangled and tied wrong. Rope was corrected to the 50 foot length.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap dispensers in the bathrooms.
Mar 18, 2026 30 demerits · 7 violations
Inspector comments: Inspection conducted with CPO Cairon Blackwell.
Immediate suspension issued
2)
15)
Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.
#2 · Water quality: disinfectant residual provided by −6
Cyanuric acid more than 100 ppm. .2535(4) The cyanuric acid level shall not exceed 100 ppm. - Immediate suspension item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor with leaves and debris. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
Missing two weirs. .2518(k) Replace missing weirs. - Intent to suspend item.
Water level above the skimmers. Overflow drain not functioning. .2518(k) Water level shall be maintained to assure skimmers are operable. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook missing a screw. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Immediate suspension item.
#18 · Premises: lifeguards present or warning signs posted −4
Pool rules sign missing. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. - Intent to suspend item.
Safety signage missing. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Intent to suspend item.
Safety signage missing. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter reading 70 GPM. Permit condition that flow meter must remain operable and be between 124 GPM for minimum turnover and 178 GPM for skimmer line limitation. .2518(b) The water circulation system shall circulate and filter the entire pool at least 4 times in 24 hours. - Corrected to 170 GPM at 2200 RPM.
Filter pressure gauge on filter closest to pump not functioning. .2519(k) Provide operational pressure gauge on filter. - Intent to suspend item.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Bathrooms being used as storage. .2526(a) Provide at least one sink and toilet for residents and guests if furthest unit is more than 300 feet from the pool at hotels, motels, condominiums and apartments.
Oct 21, 2025 32 demerits · 9 violations
Inspector comments: Inspection conducted with CPO Dionisio Acevedo.
Flow meter stuck. CPO had another Blue-White flow meter, but was the wrong size. Return line is 4” piping, ensure new Blue-White flow meter is 4”.
Intent to suspend issued
5)
16)
24)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Checking calcium hardness, but not cyanuric acid. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed no handrail to pool sunshelf. .2521(b) Provide at least one handrail on steps.
Both ladders loose. .2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 48.5 ft long. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Main door to office not self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
#18 · Premises: lifeguards present or warning signs posted −4
Pool rules sign missing. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Hoses on the ground by pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in the restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink.
Jun 3, 2025 14 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Dionisio Acevedo.
Flow meter reading 150 GPM. Minimum turnover for pool is 142 GPM, design flow is 190 GMP. Pump set at 2440 RPM. Recommend adjusting pump to get closer to design flow.
Maintenance gate doesn’t always latch. Maintain gate self-latching. Keep locked when not in use.
Back gate can only be opened from the outside with a key fob. Fix gate so that push bar works.
Inspection did not pass
5)
16)
Will need to pay a $100 re-inspection fee prior to receiving re-inspection. Re-inspection scheduled for 12:30 PM on 6/9.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place on log sheet for total alkalinity. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Left copy of state log sheet. - Pre-permit item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed no handrail to pool sunshelf. .2521(b) Provide at least one handrail on steps.
#18 · Premises: lifeguards present or warning signs posted −4
Safety signage missing. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Pre-permit item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
Mar 27, 2025 2 demerits · 1 violation
Inspector comments: Observed no non-compliant items.
Note:
No handrail on sunshelf. Plans submitted prior to State guidance.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed no handrail to pool sunshelf.
.2521(b) Provide at least one handrail on steps.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “NEXUS 485 APTS” or State ID 2060530011). Inspection type (routine vs. follow-up) is not published in the county's data.