Sep 16, 2026
8 demerits
· 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Observed one missing weir.
CPO replaced missing weir during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching.
Observed one gate unable to self-close/self-latch.
CPO repaired gate. No permit action.
View this inspection on the county portal ›
Sep 22, 2025
16 demerits
· 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 5 out of 6 weirs missing. Replace missing weirs. Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. One ladder missing both end caps. Other ladder missing one end cap.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope observed at 48ft. Must be 50ft. Immediate suspension item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter stuck at bottom. Intent to suspend item.
View this inspection on the county portal ›
Apr 9, 2025
22 demerits
· 4 violations
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Chlorine observed at 0. Possible issue with the chlorinator. Immediate suspension item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope observed at 34ft. Must be 50ft. Immediate suspension item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height.
Clear out landscaping where too high.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone callback number not working. Calls not going through to box. Emergency phone must be capable of callback. Immediate suspension item.
View this inspection on the county portal ›
Sep 10, 2024
26 demerits
· 7 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Reagents expired in test kit. Replace with in date reagents. No permit action.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 3 out of 6 weirs missing. Replace missing weirs. No permit action.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. One ladder missing both end caps. Other ladder loose.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height. No permit action.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone callback number not working. Calls not going through to box. Property recently upgraded their phone lines. Emergency phone must be capable of callback. Operator corrected and posted correct callback number on box. EHS confirmed callback capability.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter stuck at bottom. Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Less than 3’ walking space around equipment in pump room. Pool built '00. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water. - standing water on pump room floor.
View this inspection on the county portal ›
Apr 8, 2024
8 demerits
· 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Reagents expired in test kit. Replace with in date reagents. No permit action.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height. No permit action.
View this inspection on the county portal ›
Jul 24, 2023
6 demerits
· 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Window in office that opens directly onto pool deck limiting screw removed - window opens greater than 4”. Corrected during inspection.
.2537(b) All gates and doors shall be self-closing, self-latching. Gate on right side fence area not latching closed.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Entry doors from office onto pool deck not fully closing resulting in alarm not operating. Corrected during inspection.
*permit item - 30 day intent to suspend issued for gate not self closing/latching
Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Less than 3’ walking space around equipment in pump room. Pool built '00. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water. - standing water on pump room floor.
View this inspection on the county portal ›
Feb 21, 2023
14 demerits
· 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmers with accumulated debris. Emptied during inspection.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Observed linear distance between 3’ and 4’ depth markers on right side of pool perimeter distance between at 34’. Coping work completed last year and depth markers are now too far apart. Distance between depth markers cannot exceed 25’. Intent to suspend item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Entry doors from office onto pool deck do not latch shut when closed. Bells added to door as audible alarm.
Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Less than 3’ walking space around equipment in pump room. Water on pump floor. Pool built '00. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
View this inspection on the county portal ›
Sep 26, 2022
10 demerits
· 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmer baskets at time of inspection.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Clubhouse doors bell rusted, not audible at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator adjust alarm to work and corrected. Advised ensuring doors self-close completely for alarm to work or replace bells to avoid issues in the future.
Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some items stored around piping and equipment in pump room. Bag of chemicals on floor of chemical room. Water on pump floor. Pool built '00. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
Operator moved bag off floor.
View this inspection on the county portal ›
May 23, 2022
10 demerits
· 4 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate not latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height.
Operator corrected gate to self-close, self-latch.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some items stored around piping and equipment in pump room. Some chemicals in pump room. Water on pump floor. Pool built '00. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(d) Pump room floor shall be kept dry and free of standing water.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built 2000. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No paper towels in men's restroom. Provide hand drying.
View this inspection on the county portal ›
Aug 19, 2021
32 demerits
· 9 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Debris and leaves on pool floor. .2537(14) Keep pool surface and pool floor free of debris.
*Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
1 of 6 weirs missing at time of inspection .2518(k) Replace missing weirs.
*Permit item
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy becketts detached from buoy. Keep in good repair. 2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Rope tangled at time of inspection. Keep accessible.
.2530(a) Lifesaving equipment should be conveniently located. Operator replaced with new buoy, untangled rope and attached to new buoy. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates not latching at time of inspection due to system being out from lighting. .2537(b) All gates and doors shall be self-closing, self-latching. Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height.
*Permit item-Gates only
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Coping by 3 FT depth marker broken, cracked and chipped more than 1/2". .2537(3) There shall be no loose coping.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*Permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No spare pump basket time of inspection.
.2518(e) Provide a spare basket for pump.
*Permit iitem
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bag of dry sodium bicarb leaning against liquid chemical vat. Pump room without 3' clear walking space around equipment. Pool built 2000.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Operator moved chemicals and corrected.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built 2000. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in restrooms. Provide soap at sinks.
Damage to handicap chair in women's restroom. Keep fixtures in good repair.
View this inspection on the county portal ›
Feb 2, 2021
36 demerits
· 9 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records indicate pH of 6.8 for last few days and no maintenance. pH observed was 7.8. Ensure accurate records are being kept and maintenance for pool, like adding chemicals if pH is out of acceptable range.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Debris and leaves on pool floor. Scum layer on wall of pool. Pool floor starting to peel plaster at shallow end and discolored at entry. Pool floor may have to be repaired/plastered in next few years for permitting. At this time, severity does not warrant permit action.
.2537(14) Keep pool surface and pool floor free of debris.
*Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmer baskets at time of inspection.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
*Permit item
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy rope tied in middle (two broken pieces of rope). Rope measured 47' long. Must keep rope in tact and in good repair.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope required for pool is 50'.
*Immediate Suspension item. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Pool MUST REMAIN CLOSED until suspension is lifted by Health Dept.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Observed one gate piece at corner broken, allowing to be moved and creating more than 4" gap*. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height. .2528(a) Provide no openings in fence and/or gate greater than 4"x4".
*Permit item-Gate only
#22 · Premises: emergency telephone provided −6
Emergency phone not operable at time of inspection.
.2530(f) Emergency phone shall remain operable.
*Immediate Suspension item. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Pool MUST REMAIN CLOSED until suspension is lifted by Health Dept.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not working at time of inspection. Vacuum line fitting has attached piece extending greater than 2" from wall of pool. Remove fixture to keep wall of pool in good repair, no protrusions greater than 2". Provide cap.
.2518(g) Keep flow meter operational.
.2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010.
*Permit item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Liquid chemicals stored over dry in chemical storage. Pump room without 3' clear walking space around equipment. Backflow preventer broken on hose bib in equipment room. Pool built 2000.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.
View this inspection on the county portal ›
Sep 16, 2020
16 demerits
· 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
2 of 6 weirs missing at time of inspection .2518(k) Replace missing weirs. Will verify on return visit.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Two rubber stoppers observed missing on ladders. One ladder loose. .2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Observed one gate hinge broken, not self-closing, self-latching. One glass door not alarmed or latching at time of inspection. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. .2537(b) All gates and doors shall be self-closing, self-latching.
*30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Coping by 3 FT depth markers, on both sides, loose, cracked and chipped more than 1/2". .2537(3) There shall be no loose coping.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some items stored around piping and equipment in pump room. Pool built '00. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
View this inspection on the county portal ›
Jun 2, 2020
6 demerits
· 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Double door onto pool deck not self-latching or alarmed at time of inspecction.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator placed bell on door to have alarm. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Tub of chemicals stored in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Pool built 2000. Operator moved and corrected.
View this inspection on the county portal ›
Sep 17, 2019
24 demerits
· 8 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some etching on pool floor, benches and steps. Keep flooring in good repair.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Two skimmer lids with damage. Replace where needed. Intent to Suspend issued.
One skimmer missing weir. Replace. Intent to Suspend issued.
One skimmer with weir stuck. Repair.
Skimmer baskets full of leaf debris. Keep clean in order to maintain functional filtration system.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates on to pool deck with magnetic key latch. Latching mechanism below 40" (ADA required height at 42" or less) and protrudes >1/2". Raise latching mechanism to meet rule requirement or eliminate foothold. Intent to Suspend issued.
Door nearest to emergency phone not self-latching. Repair to self-latch, self-close. Intent to suspend issued.
Door on to pool deck not self-closing with audible alarm. Corrected during inspection.
Fence not 48" in height due to landscaping. Pool built in 2000, pre-2010. Repair fencing to maintain 48" height requirement.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some minor damage to coping near skimmer by bench and edge of coping near bench area. Continue to monitor. If worsens to >1/2" or hazard to public, repair as needed.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor not sloped to drain and holding water. Floor shall be sloped to drain and kept dry.
Dry chemicals stored on chemical storage room floor. Maintain dry storage up off the floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash lines to pit. Provide air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in women's restroom. Sinks in men's restroom not operable. Provide soap and keep sink faucets operable.
Damage to handicap chair in women's restroom. Keep fixtures in good repair.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention device on hose bib in pool equipment room. Provide backflow prevention device on all hose bibs.
View this inspection on the county portal ›
Apr 4, 2019
24 demerits
· 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmer baskets.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy rope too long at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator corrected to 50'.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door from gym onto pool deck not latching at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator corrected to self-latch.
Did not observe stoppers in windows onto pool deck from clubhouse, but did not attempt to open.
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.
**Permit item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Brick protruding more than 1/2" by ladder on left side. Gaps in decking greater than 1/2" at stair entrance.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
**Permit item.
#22 · Premises: emergency telephone provided −6
Kings III emergency phone not working/operable at time of inspection. .2530(f) Emergency phone shall remain operable.
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
**Immediate Suspension item. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Pool must remain closed until in compliance and verified by EHS. *Note: Phone must route to 911 and have correct information to call back to phone in case of emergency.
View this inspection on the county portal ›
Aug 27, 2018
18 demerits
· 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets with debris. Keep clean. Operator emptied. Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy wrong length (54') and tangled. Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less and easily accessible. Operator corrected to 50' and untangled.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Handhold foothold horizontal from magnet latch on gates less than 45" in height. .2528(b) Horizontals shall not be located less than 45" in height. **30 Day Intent to Suspend item. Contact Marie Daley at 704-507-6806 to lift when corrected.
Door from clubhouse onto deck not self latching and no alarm at time of inspection. Doors must self-close, self-latch or have audible alarm. Operator fixed alarm. Advised to keep alarm on at all times. Corrected.
Fencing height less than 48" in some places due to mulch. Pool fence shall be at least 48" in height measured from outside of barrier. Pool built prior to 2010.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored on floor. Store in waterproof containers or off floor.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Men's restroom had no paper towels. Provide paper towels in men's restroom.
View this inspection on the county portal ›