Sep 28, 2026
18 demerits
· 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 2 of 6 weirs missing in skimmers. One weir installed backwards, not functional. Replace missing weirs and correct improperly installed weir.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
.2530(a) Provide at least 12 ft. long pole with body hook securely attached.
Ring buoy missing rope. Replaced during inspection.
Body hook attached to pole less than 12’. Corrected to 12’ pole during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or self-closing and child protected by audible alarm. Observed both doors leading from clubhouse directly onto pool deck with latching device disabled. Operator corrected - doors both latch shut at end of inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Light burned out in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. No soap in women’s restroom.
View this inspection on the county portal ›
Jun 18, 2026
26 demerits
· 6 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Sand at bottom of pool. Clean.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. End caps missing on ladder. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached.
Body hook detached from pole.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool gate shall be at least 48" in height measured from outside of barrier.
New magnetic latches protrude more than 2inches on gates at 42” off ground creating footholds.
Raise the magnetic latches 48” off ground or install a slanted piece of metal above foothold.
Back gate missing slanted metal.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
Emergency phone not operational.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operational. Permit may not be issued without a functional flow meter.
View this inspection on the county portal ›
Oct 2, 2025
16 demerits
· 4 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Records inconsistent. Record sheet missing spot for cyanuric acid and daily drain checks.
Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. End caps missing on ladder. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope too long. CPO corrected to 50ft. No permit action.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool gate shall be at least 48" in height measured from outside of barrier.
New magnetic latches protrude more than 2inches on gates at 42” off ground creating footholds.
Raise the magnetic latches 48” off ground or install a slanted piece of metal above foothold.
Intent to suspend item
View this inspection on the county portal ›
Jun 5, 2025
16 demerits
· 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 2 out of 6 weirs missing during inspection. Replace. No permit action.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. End caps missing on ladder. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment should be conveniently located. Ring buoy rope tangled and inaccessible. CPO untangled and corrected. No permit action.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operational. Permit may not be issued without a functional flow meter.
View this inspection on the county portal ›
May 16, 2024
40 demerits
· 10 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide main drain checks daily. Some drain checks missing from January and all drain checks missing from February. Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Pump and pump motor switched out without prior approval by health department and without proper documentation. New pump does not have any labels. New motor has not received an electrical inspection. Immediate suspension item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 3 out of 6 weirs missing during inspection. Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Ladder into pool loose.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator corrected to self-close, self-latch. Door from clubhouse not latching at time of inspection and not alarmed. Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Trip hazard between “NO STEP” tile and coping resulting in an 3/4” offset. Intent to suspend item.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
.2524(c) Lighting fixtures shall not present a hazard to the public. Wall light by ladder coming out of wall. Intent to suspend item.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone not connecting to outside dial back number. Immediate suspension item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operational. Intent to suspend item.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Shower not operational at time of inspection.
View this inspection on the county portal ›
Jul 19, 2023
16 demerits
· 4 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment should be conveniently located. Ring buoy and body hook mounted on wall behind chairs, half wall and shrubbery including thorny rose bushes. Relocate to area easily accessible and conveniently located. Operator relocated during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door from clubhouse not latching at time of inspection and not alarmed.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator corrected to self-close, self-latch.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
.2530(c) Provide "Adults should not swim alone." in 1" lettering. *permit item
Current rules sign does not include all required statements. *permit item
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Shower not operational at time of inspection.
View this inspection on the county portal ›
Mar 1, 2023
24 demerits
· 6 violations
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Chlorine in pool at .08. Corrected to 2.0 during inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No TA recorded since 8/22. Records do not match actual water chemistry of pool. Ensure cl, pH, and main drain checks daily with CYA and TA checked at least weekly. Test water from pool and ensure accurately documented on records.
*permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers with accumulated debris. Cleaned during inspection..2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Locking caps on vacuum ports broken. Replace. *permit item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Gate near fitness area/bathrooms not latching closed and overhead garage door not limited or fixed closed. Corrected during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Bag of dry chemical on floor of chemical room. Liquid chemicals stored above dry chemcials.
View this inspection on the county portal ›
Jul 13, 2022
38 demerits
· 10 violations
#2 · Water quality: disinfectant residual provided by −6
Chlorine 0.4 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm. Do NOT use chlorine in skimmers, MUST bring up through chlorinator.
*Immediate Suspension item. Pool MUST REMAIN closed until suspension is lifted by Health Dept. Contact Marie Daley 704-507-6806 when in compliance to lift suspension
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Daily records not being kept at time of inspection. Missing weekly readings.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*ITS item
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Algae growth growing on pool wall and floors. .2537(14) Keep pool surface and pool floor free of debris and clean.
*ITS item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers with debris and chlorine pucks. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
*ITS item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate not latching at time of inspection..2537(b) All gates and doors shall be self-closing, self-latching.
Door from clubhouse not latching at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*ITS item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
"NO STEP" tiling not secured to deck at time of inspection, creating trip hazard. Furniture within 6' of pool.
.2537(2) Decks shall be kept in good repair.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*ITS item
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Feeder not operating properly. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions.
*ITS item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operational. .2518(g) Keep flow meter operational.
*ITS item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in pump room at time of inspection.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Chemical room not locked at time of inspection. .2533(a) The equipment and chemical room door shall have a permanent lock and be kept locked when not in use by the pool operator.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off at time of inspection. .2526(h) Shower(s) shall be provided.
View this inspection on the county portal ›
Mar 2, 2022
30 demerits
· 8 violations
#2 · Water quality: disinfectant residual provided by −6
Chlorine 0 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm.
*Immediate Suspension item. Pool MUST REMAIN closed until suspension is lifted by Health Dept. Contact Marie Daley 704-507-6806 when in compliance to lift suspension
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Daily records not being kept at time of inspection.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*ITS item
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Leaves covering main drains at time of inspection. .2537(14) Keep pool surface and pool floor free of debris.
*Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weirs missing at time of inspection.
.2518(k) Replace missing weirs.
Skimmers with debris at time of inspection.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
*permit item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate not latching at time of inspection..2537(b) All gates and doors shall be self-closing, self-latching.
Door from clubhouse not latching at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*Permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed two inlet missing eyeball fitting.
.2518(i) Provide inlet fittings in good repair.
*Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in pump room at time of inspection. Bucket in 3' clearance of equipment.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Chemical room not locked at time of inspection. .2533(a) The equipment and chemical room door shall have a permanent lock and be kept locked when not in use by the pool operator. Operator finding key to lock.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off at time of inspection. .2526(h) Shower(s) shall be provided.
View this inspection on the county portal ›
Sep 30, 2021
44 demerits
· 11 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Skimmer equalizer lines observed plugged in skimmers in all equalizer lines, 4 HP on all pool walls. No suction hazard present, but PDSC form must be updated to reflect what is in pool. Allowed 30 days to correct and submit updated PDSC form or remove plugs. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance.
*Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weirs missing at time of inspection.
.2518(k) Replace missing weirs.
*Permit item
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy and body hook behind wall and rose bushes starting to grow over path to emergency equipment. .2530(a) Lifesaving equipment should be conveniently located. Keep accessible. Advised moving equipment or cutting back shrubs for accessibility. Due to life saving equipment being available, allowed 30 days for correction of location/accessibility.
*permit item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Multiple gates not latching at time of inspection. Two windows in administrative area did not have stoppers in window and able to open greater than 4" onto pool deck. Fencing in some areas have shrubs that have grown and fence is not 48" in height from outside barrier of fence.
.2537(b) All gates and doors shall be self-closing, self-latching.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.
*Permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
"FT" tiling not secured to deck at time of inspection, creating trip hazard.
.2537(2) Decks shall be kept in good repair.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*Permit item
#18 · Premises: lifeguards present or warning signs posted −4
One sign at pool faded and not clearly visible with "Adults should not swim alone" and "Children should not use the swimming pool without adult supervision" 1" in height. Replace or remove. Other signage meets requirement, but may not be visible from all areas of pool deck. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed.
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
*Permit item
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Light fixture protruding from wall at time of inspection, creating hazard. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard.
*Permit item
#22 · Premises: emergency telephone provided −6
Large plants in front of emergency phone and signage, making phone inaccessible.
.2530(f) Emergency phone shall be accessible to all pool users. Moved plants slightly and phone can now be accessed for use, but requires permanent compliance. Allowed 30 days for correction of location/accessibility.
*Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical room lock broken and not locked at time of inspection. .2533(a) The equipment and chemical room door shall have a permanent lock and be kept locked when not in use by the pool operator.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Labels fading on piping. .2518(d) Piping and valves shall be labeled with color codes or labels.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off at time of inspection. .2526(h) Shower(s) shall be provided. Operator turned water on and shower worked, but part is being replaced.
View this inspection on the county portal ›
Apr 12, 2021
22 demerits
· 6 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Daily records not being kept at time of inspection.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*ITS item
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy rope, short, in disrepair and not securely attached to buoy at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Operator replaced rope (50') and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Multiple gates not latching at time of inspection.
.2537(b) All gates and doors shall be self-closing, self-latching.
*30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some pool furniture within 6' of pool at time of inspection.
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Operator moved chairs and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored and in use in pump room at time of inspection.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off at time of inspection. .2526(h) Shower(s) shall be provided.
View this inspection on the county portal ›