‹ Back to search

22demerits

EMBASSY SUITES AYRSLEY

1917 AYRSLEY TOWN BLVD, Charlotte, NC 28273
Year-Round Swimming Pool · NC permit/State ID 2060530330
Latest result22 demerits
Last inspectedSep 22, 2026
Inspections on record24
On record sinceJun 10, 2015

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02244 Jun 10, 2015: 0Nov 24, 2015: 4Mar 2, 2016: 18Dec 9, 2016: 26Jun 22, 2017: 6Dec 5, 2017: 18Feb 19, 2018: 20Nov 6, 2018: 6Jan 30, 2019: 20Nov 6, 2019: 12Mar 3, 2020: 6Oct 20, 2020: 4Jan 14, 2021: 12Nov 3, 2021: 32Mar 9, 2022: 44Oct 18, 2022: 16Jan 17, 2023: 20Oct 17, 2023: 10Apr 5, 2024: 28Oct 15, 2024: 16Jan 23, 2025: 20Sep 9, 2025: 26Mar 3, 2026: 14Sep 22, 2026: 22
Jun 10, 2015Lower is betterSep 22, 2026

Inspections & violations

Sep 22, 2026 22 demerits · 5 violations
Inspector comments: Conducted inspection with CPO. Pool remains on A status and in good standing. NOTES: 1) Pump at 3450 rpm to meet turnover and flow restrictions of the suction piping. Flow meter not installed correctly. NOTE: Door separating pump room and HVAC room must not be installed to lack of intake vent. ** Possible new heater - will require code enforcement permits prior to usage. Const. Date: 6/8/2015 Rope Length: 25'6
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Skimmer closest to the windows missing weir. Operator reinstalled. No permit action.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope too long. Rope required 25’6”. Operator corrected. No permit action.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Door to outside propped open. Operator removed doorstop and corrected. No permit action.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone not operable at time of inspection. Operator replaced phone and repaired. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.

View this inspection on the county portal ›

Mar 3, 2026 14 demerits · 4 violations
Inspector comments: Permit Restrictions: 1) Pump required at 3450 rpm to meet turnover and flow restrictions of the suction piping. Flow meter not installed correctly. NOTE: Door separating pump room and HVAC room must not be installed to lack of intake. Door has been removed. New heater has been installed and electrical permit received per CPO. Inspection with Rene F
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. Ladder missing endcap. .2521 Install ladders per manufacturer instructions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chair within 5’ of pool. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Operator moved and corrected.
#22 · Premises: emergency telephone provided −6
Emergency phone not operable at time of inspection. Not able to hear. .2530(f) Emergency phone shall remain operable. Operator replaced phone and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items within 3’ of equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.

View this inspection on the county portal ›

Sep 9, 2025 26 demerits · 7 violations
Inspector comments: Note: Rope for ring buoy is original to construction. Recommend replacing prior to next inspection. Lane Anderson present during the inspection. Pump changed. Verified the following during the inspection. New pump approved. 1) Electrical finaled 5/29/2025. 2) New pump Pentair SuperfloVST 342002 set to 3450 RPM meeting permit restriction. Flow meter not installed per mfg. specifications. 3) All piping - 2" line for main drain, skimmer and return. 4) (1) 2017 and (1) 2008 A10RCFRxxx drain cover. 5) (1) Pentair TR100C filter 6) (4) returns 7) (2) skimmers with EQ lines plugged per State requirement. Note: Operator is bidding for new heater. Leak on current heater. Ensure permits have been pulled and finaled with Code Enforcement prior to use.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Total alkalinity, cyanuric acid and thiosulfate reagents expired. Obtain new reagents for accurate record keeping.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some build-up on tile line around pool, especially on depth markers. Keep walls clean and in good repair. Damaged plaster in multiple locations. Concrete is showing through. Pool floor and walls do not meet 50% light reflectance. Will require repair in future. Offsets do not appear to be >1/2" at time of inspection. Some sand on pool floor. Ensure cleaning as needed to maintain pool.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Step handrail loose. Tighten.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope at 24 ft. Multiple knots in rope that were undone during the inspection. At 26 ft. with correction.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some areas around coping missing grout. One area on coping with hole. Fill/repair grout areas prior to next inspection.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Calcium hypochlorite being used in feeder that is required trichlor tablets. Verified no calcium hypochlorite in feeder at time of inspection. Operator was able to locate a bucket of trichlor tablets and replaced in the feeder during the inspection. Do NOT use calcium hypochlorite in the Pentair chlorinator onsite as it may cause an explosion. No flow meter on the chlorinator. Original construction. If ever replaced, ensure flow meter is installed.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water on floor in chemical storage room due to leak at heater. Keep floor free of standing water.

View this inspection on the county portal ›

Jan 23, 2025 20 demerits · 5 violations
Inspector comments: Immediate suspension issued for imminent hazard. Will make return visit after day of inspection to ensure chlorinator is working and no chlorine directly in pool. Contact Marie Daley at 704-507-6806 to confirm water quality is in compliance with chlorinator (no hand feeding) and visit will be made to lift suspension. Pool must remain closed with signage posted until suspension is lifted by Health Dept. “E” Immediate Suspension status
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. *Immediate suspension issued Operator removed pucks from skimmer. Will make return visit after day of inspection to ensure chlorinator is working and no chlorine directly in pool.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. Ladder missing endcap. .2521 Install ladders per manufacturer instructions. Ladder step missing non-slip tread. .2521(b) Ladders shall have slip-resistant tread.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy rope tangled at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope required 25’6”. Operator untangled and corrected.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Chlorine pucks added a directly to pool. Could not verify chlorinator is working properly at time of inspection. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water under pump on floor. .2533(d) Pump room floor shall be kept dry and free of standing water.

View this inspection on the county portal ›

Oct 15, 2024 16 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Lane Anderson. Tested cyanuric acid at 0ppm today. Facility no longer using stabilized chlorine products. Facility switched from using Triclor to Calcium Hypochlorite tablets. Still using Rainbow chlorinator. This is not approved for use with this product. Recommend replacing with a new chlorinator that is NSF approved for use with Calcium Hypochlorite. *NOTE* These two products can create an explosive reaction if mixed. Pool floor and walls missing plaster in places. Recommend replastering/patching damaged areas. Floor drain not observed in pump room. Immediate suspension issued 22) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer closest to the pump room with missing weir. .2518(k) Replace missing weirs. - Intent to suspend item. No flow in skimmer closest to the pump room. EQ and line to pump plugged. .2518(k)(3) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow the skimmer is certified for under NSF 50. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. Ladder missing endcap. .2521 Install ladders per manufacturer instructions. Ladder step missing non-slip tread. .2521(b) Ladders shall have slip-resistant tread.
#22 · Premises: emergency telephone provided −6
Posted emergency phone number goes to front desk. Front desk did not answer when number was called. .2530(f) Emergency phone shall remain operable. - Immediate suspension item. Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Immediate suspension item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Vacuum cap designed to be opened with push tab.2518(f) Provide self-closing vacuum cap designed to be opened with a tool for pools built after May 1, 2010. - Intent to suspend item.

View this inspection on the county portal ›

Apr 5, 2024 28 demerits · 6 violations
Inspector comments: Pool closed sign was placed before end of inspection.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Observed pool water hazy at time of inspection, difficult to see main drains. Immediate suspension issued.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine level at 0.4 ppm at time of inspection. Immediate suspension issued. Total chlorine was 4 - 5 ppm. Need to reach breakpoint chlorination. Cyanuric acid was approximately 30 ppm. Total alkalinity according to the record was 120 ppm. Approximately 15,500 gallons of water.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed skimmer closest to chemical/pump room missing a weir. Replace.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency not operable at time of inspection. Immediate suspension issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not operational at time of inspection. ITS issue, must be repaired.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed bathroom fixtures rusting.

View this inspection on the county portal ›

Oct 17, 2023 10 demerits · 4 violations
Inspector comments: 30 Day Intent to Suspend (ITS) issued for cyanuric acid and test kit. Contact Marie Daley at 704-507-6806 when corrected to lift ITS. Chlorine tablets with stabilizer have been used at indoor pool, cyanuric acid is so high that reading is not clear (over 300 ppm). Advised voluntarily closing pool and adjusting to acceptable level before opening to public. “W” ITS status Catie Johnson present at inspection
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid over 100 ppm in (indoor) pool at time of inspection. Reagents in test kit expired. Total alkalinity not checked. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One entry rail loose at time of inspection. .2521 Install ladders per manufacturer instructions.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bag of dry chemicals stored on floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Sink fixtures in restroom rusted and not in good repair. 2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

Jan 17, 2023 20 demerits · 5 violations
Inspector comments: 30 Day ITS for plugging skimmer equalizer lines. Contact Marie Daley 704-507-6806 when in compliance. “W” ITS status. CPO updated to Donald Moten
#3 · Water quality: pool water pH −6
PH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. CPO corrected to 7.0.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
CA on records recorded as 200. This is calcium reading. Educated operator on records reflecting correct values in correct areas. Corrected through education. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Skimmer lines missing plugs in skimmer. Disable according to State recommendations. Allowing 30 days to correct due to no suction hazard. *Contact Marie Daley at 704-507-6806 when in compliance to lift ITS
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bag of dry chemicals stored on floor. Items within 3' of piping in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Operator moved chemicals off floor. Corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Sink fixtures in restroom rusted and not in good repair. Soap dispenser not working at time of inspection. 2526(m) Keep restrooms and fixtures clean and in good repair. .2526(j) Provide soap and soap dispenser, no glass, at each sink.

View this inspection on the county portal ›

Oct 18, 2022 16 demerits · 5 violations
Inspector comments: Approved updated PDSC form with both VGBA compliant covers. Permit condition: Door to HCVAC must remain open for ventilation “A” Open for Business Inspection with Solomon Taft and Donald Moten
#5 · Water quality: daily written records of water quality and test kit kept on site −4
CA on records recorded as 200. This is calcium reading. One day missing for records. Educated operator on records reflecting correct values in correct areas. Corrected through education. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Aquastar drain covers have different color dots in middle indicating VGBA for 1 is 2008 and 1 is 2017 standards. This indicates different flow rates for PDSC. Records should reflect correct standard. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. No suction hazard. Operator updated PDSC form and submitted for approval, with correct information. Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder step missing tread at time of inspection. .2521(b) Ladders shall have slip-resistant tread.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bag of dry chemicals stored on floor. Items within 3' of piping in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Operator moved chemicals off floor.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Sink fixtures in restroom rusted and not in good repair. Soap dispenser not working at time of inspection. 2526(m) Keep restrooms and fixtures clean and in good repair. .2526(j) Provide soap and soap dispenser, no glass, at each sink.

View this inspection on the county portal ›

Mar 9, 2022 44 demerits · 12 violations
Inspector comments: Immediate Suspension for water quality and buoy. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Pool MUST REMAIN CLOSED until suspension is lifted. "E" Immediate Suspension status Other permit items: Clean pool floor, replace weirs, inlet fittings, 5' clearance, flow meter. Inspection with Scott Hegler No signature due to COVID
#2 · Water quality: disinfectant residual provided by −6
Chlorine 0 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm. Operator turned up chlorinator, but chlorine did not come up. **Immediate Suspension issued. Contact Marie Daley 704-507-6806 when in compliance to lift suspension. Pool must remain closed until lifted by Health Department.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
CA on records recorded as 200. This is calcium reading, cyanuric acid was 70. Educated operator on records reflecting correct values in correct areas. Corrected through education.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Hair and debris covering main drains. .2537(14) Keep pool surface and pool floor free of debris. *permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One entry rail loose at time of inspection. .2521 Install ladders per manufacturer instructions.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed missing inlet fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. *permit item
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy rope tangled and inaccessible at time of insoection. .2530(a) Lifesaving equipment should be conveniently located. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. *Immediate Suspension
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs and table within 5' of pool. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. *permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Digital flow meter not working at time of inspection. .2518(g) Keep flow meter operational. *Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bag of dry chemicals stored on floor. Items within 3' of piping in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower broken at time of inspection. .2526(h) Shower(s) shall be provided.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Fixtures in restroom rusted and not in good repair. Toilet soiled. .2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

Nov 3, 2021 32 demerits · 9 violations
Inspector comments: Immediate suspension issued for water quality. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. "E" Immediate Suspension Other permit items: Replace missing inlet fitting, keep flow meter operational. Inspection with Justin Law and Scott Hegler No signature due to COVID
#2 · Water quality: disinfectant residual provided by −6
Chlorine under 1 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm. Operator turned up chlorinator, but chlorine did not come up. **Immediate Suspension issued. Contact Marie Daley 704-507-6806 when in compliance to lift suspension. Pool must remain closed until lifted by Health Department.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid observed at 200 ppm at time of inspection. Establishment using stabilized chlorine tablets due to shortage of supply. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. *Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One entry rail loose at time of inspection. .2521 Install ladders per manufacturer instructions. Operator tightened and corrected.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed missing inlet fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. *permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chair within 5' of pool. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. Operator moved chair and corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Digital flow meter not working at time of inspection. .2518(g) Keep flow meter operational. *Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bag of dry chemicals stored on floor. Items within 3' of piping in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Fixtures in restroom rusted and not in good repair. .2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

Jan 14, 2021 12 demerits · 3 violations
Inspector comments: 6) Skimmer equalizer lines plastered on wall, but not plugged in skimmer. No suction hazard present, but State Recommendation includes emptying water in line and plugging in skimmers. 2" pipe. No signature due to COVID. Inspection with Scott Hegler and Natalie Miller Report to
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chair and table within 5' of handrail into pool. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. Moved table and chair and corrected.
#22 · Premises: emergency telephone provided −6
Emergency phone not operable at time of inspection and signage with phone number has been removed. .2530(f) Emergency phone shall remain operable. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator replaced phone to be operator and posted signage with all correct information. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bag of dry chemicals stored on floor. Items within 3' of piping in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.

View this inspection on the county portal ›

Oct 20, 2020 4 demerits · 1 violation
Inspector comments: Inspection with Scott Hegler. No signature due to COVID-19. Report to Scott Hegler
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs within 5' of pool and handrails. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. Operator moved furniture and corrected.

View this inspection on the county portal ›

Mar 3, 2020 6 demerits · 1 violation
Inspector comments: "E" Immediate Suspension status. 5) CA being recorded on records as calcium, above 150. "CA" on records indicate cyanuric acid. This is indoor pool and cyanuric acid is not added to pool. Educated operator on ensuring records accurately reflect correct readings for each item. 22) Static in emergency phone, but operable. Ensure phone stays operable and accessible with ability to hear on both ends in case of emergency. Operator adjusted phone for better hearing.
#2 · Water quality: disinfectant residual provided by −6
Chlorine under 1 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm. Operator turned up chlorinator, but chlorine did not come up. **Immediate Suspension issued. Contact Marie Daley 704-507-6806 when in compliance to lift suspension. Pool must remain closed until lifted by Health Department.

View this inspection on the county portal ›

Nov 6, 2019 12 demerits · 3 violations
Inspector comments: ITS for inlet fitting and weirs. 5) "CA" being recorded is calcium with ranges from 120-180, but CA indicates cyanuric acid on form. If pool is not using cyanuric acid this is not a required weekly testing. Ensure records accurately reflect correct readings for each item. 22) Static in emergency phone, but operable. Ensure phone stays operable and accessible with ability to hear on both ends in case of emergency.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
1 of 2 weirs missing at time of visit. .2518(k) Replace missing weirs. **30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when corrected to lift ITS.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed missing inlet fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. *ITS item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed a deck furniture within 5ft of the pool deck. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Operator corrected by relocating furniture.

View this inspection on the county portal ›

Jan 30, 2019 20 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Nov 6, 2018 6 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Feb 19, 2018 20 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Dec 5, 2017 18 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Jun 22, 2017 6 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Dec 9, 2016 26 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Mar 2, 2016 18 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Nov 24, 2015 4 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Jun 10, 2015 0 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “EMBASSY SUITES AYRSLEY” or State ID 2060530330). Inspection type (routine vs. follow-up) is not published in the county's data.