‹ Back to search

16demerits

RESIDENCES @ BROOKLINE

8816 ASPINWALL DR, Charlotte, NC 28216
Year-Round Swimming Pool · NC permit/State ID 2060530334
Latest result16 demerits
Last inspectedOct 28, 2026
Inspections on record26
On record sinceSep 25, 2015

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01734 Sep 25, 2015: 0Jun 7, 2016: 8Sep 21, 2016: 6Mar 21, 2017: 20Oct 26, 2017: 34May 9, 2018: 30Nov 5, 2018: 12Jan 22, 2019: 34Oct 17, 2019: 6May 26, 2020: 4Oct 14, 2020: 6Mar 29, 2021: 8Nov 3, 2021: 0May 4, 2022: 0Sep 13, 2022: 10Mar 28, 2023: 22Jun 7, 2023: 6Jun 8, 2023: 0Oct 24, 2023: 20Mar 20, 2024: 12Apr 19, 2024: 0Nov 12, 2024: 22Mar 11, 2025: 22Nov 17, 2025: 22Mar 23, 2026: 10Oct 28, 2026: 16
Sep 25, 2015Lower is betterOct 28, 2026

Inspections & violations

Oct 28, 2026 16 demerits · 4 violations
Inspector comments: POOL IS NOT APPROVED FOR NIGHT SWIMMING. SIGNS GIVE THE CLOSING TIME OF THE POOL AS 10PM. THE POOL CANNOT BE OPEN FOR SWIMMING AFTER SUNSET OR BEFORE SUNRISE. CHANGE THE SIGNS TO REFLECT THIS, FOR EXAMPLE THEY COULD READ “POOL OPEN FOR SWIMMING FROM DAWN TO DUSK” OR “POOL OPEN FOR SWIMMING FROM SUNRISE TO SUNSET”. MAIN DRAIN COVERS EXPIRE 5/15/2030 POOL IS ISSUED AN INTENT TO SUSPEND FOR THE MISSING WEIRS, THE GATES NOT LATCHING, AND THE MESH BEING DAMAGED ON ONE GATE ALLOWING A LARGE GAP WITHIN 18 INCHES OF THE BAR. DEADLINE IS 11/27/2026. FAILURE TO CORRECT THE ISSUES MAY RESULT IN CLOSURE OF THE POOL. CONTACT C. ELMORE AT 704-507-6814 WHEN THE CORRECTIONS ARE MADE. THE POOL HEATER IS TURNED OFF.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed gaps in the record book. The checks must be made and recorded for every day the pool is open.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 4 weirs missing out of 7. Replace all of the weirs.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed gate mesh damaged to a point where their is a gap greater than 1/2 inch. This must be corrected. Observed 2 of the gates not latching. This must be corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed some deck damage. Correct any deck damage.

View this inspection on the county portal ›

Mar 23, 2026 10 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Jeff Kiker. Coping chipping at sunshelf. Maintain in good condition.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer basket cracked. .2518(k) Replace missing or damaged skimmer basket. - Corrected, operator has it on order.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.

View this inspection on the county portal ›

Nov 17, 2025 22 demerits · 5 violations
Inspector comments: Inspection conducted with inspector Niejel Wilkins, and CPO Jeff Kiker. Inspection led by Niejel Wilkins. Intent to suspend issued 7)
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Leaves on pool floor and floating on pool surface. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers not functioning. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Corrected, pump basket was full of leaves.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope too short. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4” in diameter. - Corrected.
#22 · Premises: emergency telephone provided −6
Kings III operator not able to hear us. .2530(f) Emergency phone shall remain operable. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.

View this inspection on the county portal ›

Mar 11, 2025 22 demerits · 6 violations
Inspector comments: Inspection conducted with supervisor Hope McIntosh and CPO Jeff Kiker. Office phone number posted at emergency phone. To avoid confusion, recommend only posting phone number for emergency phone. Intent to suspend issued 7) 17)
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor with leaves and debris. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. Missing 2 of 7 weirs. .2518(k) Replace missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail loose. .2521 Install handrails per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope too short. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4” in diameter. - Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck chairs beside the pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected. Some skimmer lids appear to have been pushed up from frost heave, creating trip a hazard. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Fan off in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. - Corrected. Fan off in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. - Corrected.

View this inspection on the county portal ›

Nov 12, 2024 22 demerits · 6 violations
Inspector comments: Inspection conducted with inspectors Noel Lamarre, Jeremy Stawinsky, and CPO Jeff Kiker.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Recently changed to Greystar log sheet. No place for main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Corrected. Operator will check main drains instead of lights.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. Missing 2 of 7 weirs. .2518(k) Replace missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail loose. .2521 Install handrails per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 46.5 feet long. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4” in diameter. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
More than 2” gap under the fence near grill area. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Corrected. Gate by clubhouse not self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.

View this inspection on the county portal ›

Apr 19, 2024 0 demerits · 0 violations
Inspector comments: Visit conducted with CPO Jeff Kiker. Observed good record keeping. Intent to suspend lifted.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Mar 20, 2024 12 demerits · 3 violations
Inspector comments: Inspection conducted with inspector Daniel Squirewell and CPO Jeff Kiker. Motor on filtration pump recently replaced. Electrical permit E4552347 passed inspection 2-7-2024.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent main drain or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. Missing 1 of 7 weirs. .2518(k) Replace missing weirs.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.

View this inspection on the county portal ›

Oct 24, 2023 20 demerits · 5 violations
Inspector comments: Inspection conducted with inspector Jordan Johnson and CPO Jeff Kiker. *NOTE* outdoor pool with an attached heater. Heater not operating at the time of inspection. Skimmer equalizer lines at sunshelf recently plastered over on the sunshelf and plugged in the skimmer per state guidelines. PDSC form updated and verified. The rest of the equalizer lines were abandoned when the pool was recently replastered.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets full. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. Missing 1 of 7 weirs. .2518(k) Replace missing weirs.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
More than 2” gap under the fence near grill area. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Corrected.
#18 · Premises: lifeguards present or warning signs posted −4
Pump room recently painted. Signage taken down. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Corrected. Pump room recently painted. Signage taken down. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Corrected. Pump room recently painted. Signage taken down. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Corrected.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
Pump room recently painted. Signage taken down. .2530(d) Provide a sign prohibiting pets and glass containers in the pool area. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Spare pump basket not observed. .2518(e) Provide a spare basket for pump.

View this inspection on the county portal ›

Jun 8, 2023 0 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Jun 7, 2023 6 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Mar 28, 2023 22 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Sep 13, 2022 10 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

May 4, 2022 0 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Nov 3, 2021 0 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Mar 29, 2021 8 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Oct 14, 2020 6 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

May 26, 2020 4 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Oct 17, 2019 6 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Jan 22, 2019 34 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Nov 5, 2018 12 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

May 9, 2018 30 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Oct 26, 2017 34 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Mar 21, 2017 20 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Sep 21, 2016 6 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Jun 7, 2016 8 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Sep 25, 2015 0 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “RESIDENCES @ BROOKLINE” or State ID 2060530334). Inspection type (routine vs. follow-up) is not published in the county's data.