OVERTURE PROVIDENCE

6805 WALNUT BRANCH LN, Charlotte, NC 28277
Year-Round Swimming Pool · NC permit/State ID 2060530547
Latest result12 demerits
Last inspectedOct 6, 2026
Inspections on record14
On record sinceJan 27, 2020

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0714 Jan 27, 2020: 0Jul 30, 2020: 4Feb 24, 2021: 14Oct 21, 2021: 0Apr 19, 2022: 4Aug 17, 2022: 0Mar 1, 2023: 12Aug 29, 2023: 4Mar 27, 2024: 4Nov 25, 2024: 8Feb 4, 2025: 12Jul 31, 2025: 6May 13, 2026: 10Oct 6, 2026: 12
Jan 27, 2020Lower is betterOct 6, 2026

Inspections & violations

Oct 6, 2026 12 demerits · 3 violations
Inspector comments: Conducted inspection with new CPO Roddrick. Pool remains on A status and in good standing. Const. Date: 10/10/2019 Rope Length: 35' Night Swim?: N
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. PH observed at 6.8. Operator corrected to 7.4. No permit action.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Two records for October missing. Remaining records complete and accurate. Ensure consistent daily records are maintained. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in equipment room. Fan not working in chemical storage. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.

View this inspection on the county portal ›

May 13, 2026 10 demerits · 3 violations
Inspector comments: Conducted inspection with CPO. Intent to suspend issued for flow meter and records. Items must be corrected by May 31st or new permit shall not be issued. Const. Date: 10/10/2019 Rope Length: 35' No night swimming.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Weekly recordings for cyanuric acid and total alkalinity missing since February. Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operational. Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in equipment room. Fan not working in chemical storage. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.

View this inspection on the county portal ›

Jul 31, 2025 6 demerits · 2 violations
Inspector comments: Inspection with Tomeka Gaillard. No night swimming. Discussed record keeping and monitoring water quality daily. If pool is open, it must be checked daily, by any responsible persons. If pool is not checked, pool should be voluntarily closed. Example, no staff present on Sunday to check pool. Pool should be voluntarily closed until verified in compliance then re-open. Contact Marie Daley 704-507-6806 with questions. No permit action at this time. CPO working with management to resolve. If issue persists, permit action will be taken.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing entries for weekends/days CPO not present. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Lack of severity does not warrant permit action at this time. All other records are accurate and maintained. Advised staff present on days main pool operator is absent, should be trained and responsible for checking water quality, temperature and main drains daily and voluntarily closing pool if not in compliance until issues are mitigated.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in equipment room. Fan not working in chemical storage. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.

View this inspection on the county portal ›

Feb 4, 2025 12 demerits · 4 violations
Inspector comments: ITS for records. Contact Marie Daley at 704-507-6806 when records are accessible to lift ITS. Main drains expire August 2026. Replace and submit updated PDSC for approval PRIOR to expiration to avoid permit action. No Night Swimming CPO updated to Tomeka Gaillard
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records not accessible. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item .2535(11) The pool operator must maintain records for at least six months.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs and table within 6 foot of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals used and stored in equipment room. No clear walking space around equipment. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off at time of inspection. .2526(h) Shower(s) shall be provided.

View this inspection on the county portal ›

Nov 25, 2024 8 demerits · 3 violations
Inspector comments: Conducted inspection with CPO Tomeka. Pool remains on A status and in good standing.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Reagents expired. Replace with fresh reagents. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals stored in pump room. Move to designated chemical storage room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Provided shower not working.

View this inspection on the county portal ›

Mar 27, 2024 4 demerits · 1 violation
Inspector comments: Ensure that the deck is maintained such that the polymeric sand remains intact or is replaced as needed. Ensure moss and plant growth is removed so it does not damage the deck.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed some deck furniture too close to the pool. Items were moved. -CDI

View this inspection on the county portal ›

Aug 29, 2023 4 demerits · 2 violations
Inspector comments: No Night Swimming. Some reagents expired and expiring soon. Advised replacing prior to expiration to avoid issues and inaccurate readings. Inspection with Ryan Hubbard
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some water around pump in equipment room. Chemicals used and stored in equipment room. No clear walking space around equipment. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One sink in men’s restroom not working. No hand drying in men’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair. Operator placed paper towels in men’s restroom and corrected.

View this inspection on the county portal ›

Mar 1, 2023 12 demerits · 3 violations
Inspector comments: No Night Swimming. Inspection with Ryan Hubbard.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#22 · Premises: emergency telephone provided −6
Emergency phone not audibly ringing back at time of inspection. .2530(f) Emergency phone shall remain operable. Operator corrected to be audible in case of emergency to callback. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some water around pump in equipment room. Chemicals used and stored in equipment room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(d) Pump room floor shall be kept dry and free of standing water.

View this inspection on the county portal ›

Aug 17, 2022 0 demerits · 0 violations
Inspector comments: Inspection completed with Ryan Hubbard present. Observed 1 missing return line fitting. Replace. Observed emergency phone functioning adequately but with no audible ring back. The Health Department recommends the emergency phone be capable of producing an audible ring back or by answering automatically.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 19, 2022 4 demerits · 1 violation
Inspector comments: Inspection completed with Ryan Hubbard present.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed some chemicals expired. Replace expired chemicals.

View this inspection on the county portal ›

Oct 21, 2021 0 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Feb 24, 2021 14 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Jul 30, 2020 4 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Jan 27, 2020 0 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “OVERTURE PROVIDENCE” or State ID 2060530547). Inspection type (routine vs. follow-up) is not published in the county's data.