12demerits
BRILEY APARTMENTS
10731 SURREY GREEN LN, Matthews, NC 28105
Year-Round Swimming Pool · NC permit/State ID 2060530618
Latest result12 demerits
Last inspectedSep 21, 2026
Inspections on record13
On record sinceMay 28, 2021
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 28, 2021Lower is betterSep 21, 2026
Inspections & violations
Sep 21, 2026 12 demerits · 4 violations
Inspector comments: Issued 30 Day Intent to Suspend (ITS) for gates and flow meter. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS
“W” Status
For night swimming, send picture verification of sufficient light to M. Daley before dawn or after dusk.
Pool not heated.
Inspection with Tyrell Carey
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate not latching. .2537(b) All gates and doors shall be self-closing, self-latching.
*permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operational at time of inspection. .2518(g) Keep the flow meter operational.
*permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items in pump room being stored, lights and ladder. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One sink in women’s restroom not operable.
.2526(m) Keep restrooms and fixtures clean and in good repair.
Mar 26, 2026 10 demerits · 2 violations
Inspector comments: Inspection completed with Jeff McShane and Dariel Shazier present.
Note- Observed ring buoy beckets in poor repair but still with structural integrity. Replace within 30 days or permit may be suspended.
Intent to suspend permit issued for gate near fire place not self-closing. Correct within 30 days.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed the pH at 6.8. CDI- adjusted to 7.2.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate near fire place not self-closing. Intent to suspend issued. Correct within 30 days.
Oct 7, 2025 4 demerits · 1 violation
Inspector comments: Inspection completed with Dariel Shazier and Jeff McShane present.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate and one door not self-closing and self-latching. CDI- both repaired.
Mar 19, 2025 0 demerits · 0 violations
Inspector comments: Inspection completed with Jeff McShane and Dariel Shazier.
No violations noted during inspection.
No violations were recorded for this inspection.
Sep 11, 2024 0 demerits · 0 violations
Inspector comments: Inspection completed with Dariel Shazier and Julio Montenegro.
No violations noted during inspection.
No violations were recorded for this inspection.
Apr 4, 2024 0 demerits · 0 violations
Inspector comments: Inspection completed with Dariel Shazier and Jeff McShane present.
Observed beckets on ring buoy beginning to fray. CDI- replaced with new ring buoy.
No violations were recorded for this inspection.
Aug 16, 2023 4 demerits · 1 violation
Inspector comments: Inspection completed with Dariel Shazier and Jeff McShane.
Night swimming verified during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed stuck flow meter.
Mar 23, 2023 20 demerits · 4 violations
Inspector comments: Inspection completed with David Parker present.
General comment: ensure window limiters are installed on any ground level windows that face onto the pool deck.
NOTE: Observed PDSC paperwork indicate Lawson drain covers installed. Actual drain covers installed are Waterway covers. No suction hazard due to flow ratings. Submit new PDSC paperwork within 1 week or permit may be suspended.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.4ppm. CDI- adjusted through chlorine feeder to 1.0ppm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris accumulation in skimmers. CDI- cleaned.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope at 53 feet. CDI- adjusted to 45 feet.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter non-operational.
Sep 21, 2022 8 demerits · 2 violations
Inspector comments: Pool is approved for night swimming. C. Elmore will follow-up at a later date to verify the night swimming lighting.
INTENT TO SUSPEND ISSUED. 30 DAY DEADLINE 10/21/2022. IF ISSUES ARE NOT CORRECTED BY THE DEADLINE THE POOL WILL BE CLOSED UNTIL THE ITEMS ARE CORRECTED. CONTACT C. ELMORE AT 704-507-6814 WHEN CORRECTIONS ARE MADE.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed 3 spaces in the apartment patio fence next to the social entrance that are slightly wider than 4 inches. I.T.S. Issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed the vacuum line to still having suction even if the valve is shut off due to infiltration of rocks into the valve. Fix the system so that the suction is able to be completely turned. -I.T.S. Issued.
Apr 13, 2022 4 demerits · 1 violation
Inspector comments: C. ELMORE WILL FOLLOW-UP AFTER SUNSET TO CONFIRM THE LIGHTING FOR NIGHT SWIMMING.
CPO AGREED TO EMAIL OF THE INSPECTION REPORT.
POOL HAS PASSED INSPECTION. PERMIT WILL BE AVAILABLE FOR PRINT ON-LINE AT https://www.mecknc.gov/HealthDepartment/EnvironmentalHealth/Pages/Default.aspx
AND THE PERMIT STICKER WILL BE MAILED.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
OBSERVED MAIN DRAIN CHECK MISSED ON THE LOG SHEET. C.D.I. BY EDUCATION AND HAVING THE CPO PROPERLY FILL OUT THE LOG FOR TODAY.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Oct 13, 2021 6 demerits · 1 violation
Inspector comments: CPO AGREED TO EMAIL COPY OF REPORT
NO SIGNATURE DUE TO COVID-19 PRECAUTIONS.
CONTINUE TO FOLLOW ALL RELEVANT COVID RULES
#3 · Water quality: pool water pH −6
Observed pH to be 8.1 upon arrival.
.2535(1) Maintain pH at 7.2 to 7.8.
Corrected to 7.6 C.D.I.
Jun 7, 2021 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED. ITEMS FROM PREVIOUS INSPECTION, PHONE ADDRESS ISSUE AND FENCE ISSUE, HAVE THE DEADLINE OF 6/27/2021.
CONTINUE TO FOLLOW ALL RELEVANT COVID RULES
POOL HAS PASSED INSPECTION AND BEEN ISSUED THEIR PERMIT STICKER.
PAPER PERMIT WILL BE AVAILABLE ON-LINE FOR DOWNLOAD AND PRINTING AT OUR POOLS WEBSITE.
POST PERMIT AND STICKER WERE VISIBLE AT POOL AREA.
CPO AGREED TO EMAIL COPY OF REPORT
NO SIGNATURE DUE TO COVID-19 PRECAUTIONS.
POOL BUOY THROW ROPE WAS FOUND TO BE 45FT. LONG. POOL IS 30FT. WIDE. 45FT. LONG IS THE CORRECT ROPE LENGTH.
No violations were recorded for this inspection.
May 28, 2021 0 demerits · 0 violations
Inspector comments: Onsite visit with Andrew Jones from Hot Springs for return construction. All items corrected from previous visit except for emergency phone. Pool cannot be assigned individual address due to mailing address. Leasing office address is 10731 Surrey Green Ln, Matthews, NC. Pool phone is listing 10731 Surrey Green Ln. with 911. Phone shall be designated as "pool phone" if address is not 10735 Surrey Green Ln. 911 should be able to verify that phone is identified as pool phone. Given 30 days to correct with 911/Spectrum. Temporary signage added with 10731 Surrey Green Ln. If not corrected within 30 days, the permit will be suspended.
Note: Barrier by pump room. Temporary fencing added on top of barrier near handrail. Per State, handrail is not affixed to the barrier and required per ADA so approved. Facility will install permanent replacement of taller fence. Backorder due to Covid. When installed, ensure meeting .2528.
Construction final passed with restriction above.
Permit issued for no night swimming. A follow-up inspection will be conducted by the assigned inspector within 2 weeks.
Note: Facility provided signage does not meet code requirements. Missing No Glass and shower signage. If generic signage removed, pool signage must meet code requirements.
Permit Restriction
1) Salt not approved as primary chlorination.
Filtration – Pentair Challenger CHII-NI-2F, 2 hp pump
Feature – Pentair Challenger CFII-NI-1.5F, 1.5 hp pump
Both filtration and feature pumps pull through same set of main drains – Lawson MLD-SG-0909 drain covers. Skimmer equalizers plugged in skimmer.
Max Depth – 4 ½ ft.
Pool Width – 40 ft.
Rope Length – 50 ft.
No violations were recorded for this inspection.