6 demerits
· 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Side gate not latching at time of inspection. Double glass door sensor to pool deck not turning off, allowing door to be opened without latching or alarm. Yoga studio door not staying latched or alarmed, sensor allows door to be opened. There is garage door that opens onto pool deck in yoga room. Fence with gap greater than 2” under it with rocks. Some mesh missing from bottom right of left side gate with opening greater than 1/2” within 18” of latching mechanism.
.2528(a) Maintain 2" or less under fence and/or gate (post-May 1, 2010).
.2537(b) All gates and doors shall be self-closing, self-latching.
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
.2528(a) Ground level doors shall be self-closing, self-latching or self-closing and child protected by audible alarm.
*Permit item
Operator filled in gaps with rocks under fence.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak at return, floor wet in pump room. Some tubs of chemicals stored in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
View this inspection on the county portal ›
Aug 18, 2025
24 demerits
· 5 violations
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0ppm. Permit suspended.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed approximately 1 week worth of main drain safety checks not being recorded in pool log for August, 2025. Observed no issues with previous months so no permit action taken.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 missing weir.
Observed debris accumulation around inside ring top of skimmers.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
Observed patron inside pool area with glass drinking cup. CDI- glass was removed.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone is unable to receive incoming calls. This was tested using a Verizon mobile phone, a T-Mobile mobile phone, and a land line phone. All 3 phones were unable to connect with the emergency phone.
View this inspection on the county portal ›
Oct 17, 2023
12 demerits
· 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 weir missing out of 6 total weirs.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Observed chlorine feeder damaged in such a way that pump cannot be operable. Pool cannot have circulation flow until feeder is fixed.
Immediate Suspension Issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed pump not able to be operated to provide flow for circulation as required. Immediate Suspension Issued.