20demerits
ADDISON ONE15
1050 BECKONING BV, Charlotte, NC 28269
Year-Round Swimming Pool · NC permit/State ID 2060530781
Latest result20 demerits
Last inspectedSep 15, 2026
Inspections on record4
On record sinceJul 3, 2025
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 3, 2025Lower is betterSep 15, 2026
Inspections & violations
Sep 15, 2026 20 demerits · 6 violations
Inspector comments: Inspection conducted with EHS Kurtis Nelson and CPO Michael Blackmon
Filtration system at 89GPM, feature system at 35 GPM
Intent to suspend issued 16) .2537(b) All gates and doors shall be self closing, self latching. Gate at rear of pool near grill area does not self latch.
Contact Inspector Kurtis Nelson 980-378-7896 once fence is repaired.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Some buildup observed in bottom and side of pool. Need to clean. No permit action.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. .2521 Install ladders per manufacturer instructions.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. One return on bottom of pool missing. Need to replace.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Gate at rear of pool near grill area does not self latch. Shown to CPO during inspection. ITS issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Skimmer lid starting to sink into deck. Grout is missing around some depth marking tiles. Need to repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies. Bad of chemicals observed stored on floor in pump room.
Mar 23, 2026 10 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Michael Blackmon.
Filtration system at 105 GPM, feature system at 38 GPM.
Intent to suspend issued
16)
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. .2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Piece of plexiglas missing along top of one of the gates. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Soap dispenser in handicap stalls not working. .2526(j) Provide soap and soap dispenser, no glass, at each sink.
Aug 14, 2025 8 demerits · 2 violations
Inspector comments: Inspection conducted with CPO Mike Blackmon.
Pool surface area 1,940 sq ft. Requires 8 feet of clear walkway around the pool.
Ensure windows that open on to pool deck are not capable of opening > 4 inches.
Permit condition that flow meter on feature return must remain operable and at 62 GPM or less due to flow restriction of the suction line. Observed at 52 GPM today.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. .2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook not attached to pole. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Corrected.
Jul 3, 2025 0 demerits · 0 violations
Inspector comments: Observed no non-compliant items.
Contact KingsIII and add "Pool Phone" to information line for better location information in an emergency.
Feature flow: 51gpm
Permit Restriction: Flow meter on feature return must remain operable. Flow shall not exceed 62 gpm due to flow restriction of the suction line.
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ADDISON ONE15” or State ID 2060530781). Inspection type (routine vs. follow-up) is not published in the county's data.