PAVILION VILLAGE APARTMENTS
131 GRACYN OLIVIA DR, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530784
Latest result26 demerits
Last inspectedSep 17, 2026
Inspections on record4
On record sinceJun 20, 2025
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 20, 2025Lower is betterSep 17, 2026
Inspections & violations
Sep 17, 2026 26 demerits · 6 violations
Inspector comments: Inspection completed with Tommy Rivera present.
Permit suspended for following items listed below. Once corrected, contact Eli Freese at 704.621.2298 to verify and reopen pool. Maintain pool closed signs posted.
Note- ring buoy in poor repair. This must be corrected prior to reopening.
1. Emergency phone non operational.
2. No automatic chlorine feeder currently installed.
3. Worn/ damaged ring buoy.
The items listed below are 30 day intent to suspend items. Correct these items within 30 days after the permit is reinstated.
1. Gate not self-closing near sun shelf due to friction with concrete walkway.
2. 3x3 square hole in pool deck where handicap chair was installed must be sealed so as to not cause a trip hazard.
3. Detached ‘no diving’ marker on pool deck.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed 1 ‘no diving’ tile detached from pool deck. Reattach.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate at sun shelf side of pool not self-closing due to friction with cement walkway. Correct so gate self-closes self-latches or is no longer a gate access.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed 3x3 inch square hole in pool deck where handicap chair was previously installed. Close hole in pool deck so it does not constitute a trip hazard.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone non-operational. Permit suspended.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Observed facility does not have an automatic chlorine feeder currently installed. Permit suspension issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep the flow meter operational. Observed the flow meter non operational.
Mar 30, 2026 26 demerits · 6 violations
Inspector comments: POOL IS NOT APPROVED FOR NIGHT SWIMMING. SIGNS SAY POOL HOURS ARE 9AM-9PM. POOL CANNOT BE SHOWING OPEN HOURS AFTER SUNSET OR BEFORE SURISE WITHOUT AN APPROVAL FOR NIGHT SWIMMING. IF YOU WISH TO HAVE THE POOL INSPECTED FOR NIGHT SWIMMING, CONTACT C. ELMORE AT 704-507-6814. CURRENTLY THE POOL CAN ONLY BE OPEN FOR SWIMMING DAWN TO DUSK. CORRECT THE
SIGNS.
INTENT TO SUSPEND ISSUED FOR ITEMS THAT NEED CORRECTION. DEADLINE IS 4/29/2026. FAILURE TO CORRECT THE ITEMS BY THIS POINT MAY RESULT IN CLOSURE OF THE POOL.
OBSERVED PDSC FORM TO GIVE AQUASTAR 12MF COVERS FOR THE MAIN DRAIN COVERS. OBSERVED AQUASTAR 1216 COVERS ACTUALLY INSTALLED. THE GPM FOR THE 1216 COVERS IN THIS POOL APPEARS TO BE 500 GPM WHICH IS SUFFICIENT TO HANDLE THE PUMP FLOW, BUT CORRECTED PDSC INFORMATION MUST BE SENT TO THE HEALTH DEPARTMENT AND APPROVED. THIS MUST BE DONE BEFORE APRIL 7TH 2O26. FAILURE TO HAVE THIS CORRECTED WILL RESULT IN THE CLOSURE OF THE POOL.
MAIN DRAIN COVERS EXPIRE 6/2/2030
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (4) Lower and maintain cyanuric acid at or below 100 ppm.
Observed no records kept since February 20th 2026. Records must be properly kept going forward. I.T.S. Issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Required length for this pool is 50 feet. Observed ring buoy to have 47.5 foot rope when 50 foot rope is required. Rope was corrected to 50ft. -CDI.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed the plastic shields on the gates to be too short to comply with the 18 inch requirement. I.T.S. Issued. Correct all of the gates.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed furniture to be too close to the pool. Items were moved back to the 6 foot mark.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed the sign that was present to have letters that are 1/4 inch too short. This sign must be corrected. I.T.S. Issued. All of the letters must be 4 inches tall or taller.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter to be non-functional. Correct the flow meter. Pool does not have a flow restriction.
Oct 10, 2025 14 demerits · 3 violations
Inspector comments: Permit suspended for rope length. Pool shall remained closed until 50 ft rope provided.
Contact inspector when rope is provided.
Inspection performed by Kurtis Nelson REHS
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Repeat. Observed debris in skimmers. Keep skimmers free of debris.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope for ring buoy is 41ft. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed chairs and stool within 6 ft of pool.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Jun 20, 2025 4 demerits · 1 violation
Inspector comments: Permit sticker issued onsite
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmers. Keep skimmers free of debris.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “PAVILION VILLAGE APARTMENTS” or State ID 2060530784). Inspection type (routine vs. follow-up) is not published in the county's data.