2demerits
BAINBRIDGE MALLARD CREEK
3012 ARDISIA DR, Charlotte, NC 28269
Year-Round Swimming Pool · NC permit/State ID 2060530824
Latest result2 demerits
Last inspectedSep 16, 2026
Inspections on record4
On record sinceSep 26, 2025
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Sep 26, 2025Lower is betterSep 16, 2026
Inspections & violations
Sep 16, 2026 2 demerits · 1 violation
Inspector comments: POOL IS NOT APPROVED FOR NIGHT SWIMMING. THE POOL CANNOT BE OPEN FOR SWIMMING AFTER SUNSET OR BEFORE SUNRISE.
MAIN DRAIN COVERS EXPIRE 8/25/2030
NOTE: Pump at 3450 RPM - or - Flow meter must remain operable with flow at 109 gpm to 138 gpm to meet turnover and flow restriction of the suction pipes.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed leak in the line for the automatic feeder system. System has been turned off and pH is being adjusted by hand feeding. Chlorine is provided through the back-up erosion feeder. Chlorine cannot be hand-fed into the pool for normal reputation, only for shocking when the pool is closed. Fix the leak.
Mar 31, 2026 20 demerits · 5 violations
Inspector comments: Inspection conducted with CPO Daniel Ubiles.
Pool recently had new coping and wall tiles installed. Polymetric sand not yet added. Ensure that deck is structurally sound with no gaps or offsets > 1/2 inch. Area above one of the skimmers missing underlayment to keep Polymetric sand from falling into the skimmers. Ensure that this is permanently addressed with a product designed for this purpose. Must be corrected within 30 days or permit will be suspended.
Immediate suspension still in place.
3)
Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.
#3 · Water quality: pool water pH −6
PH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir missing, the rest of the weirs stuck, do not move freely. .2518(k) Provide functioning weirs. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Polymetric sand missing between coping and deck. Some deck pavers loose or missing. .2537(2) Decks shall be structurally sound and kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Chemical controller reading 7.4. Got < 6.8 on my test kit. Ensure chemical controller is properly calibrated. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Some items stored by pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Oct 14, 2025 14 demerits · 4 violations
Inspector comments: Inspection performed with Daniels Ubiles CPO.
Permit condition that flow meter must remain operational with flow of 109 GPM to 138 GPM to meet minimum turnover and restriction of the suction pipes. Observed at 128 GPM.
Pool closed for the season, pool closed signs not posted. Ensure pool signs are posted whenever the pool is closed and note in the pool log book.
Intent to suspend issued
5)
7)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records are being kept.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor was observed with an accumulation of leaves.
.2537(14) Keep pool surface and pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir was observed not installed properly.
.2518(k) Provide functioning weirs.
Skimmer basket observed with an accumulation of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals were observed in the pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Sep 26, 2025 0 demerits · 0 violations
Inspector comments: OSV to pool for return construction with Ben Caldwell, GC, Ryan Price, pool builder and CPO, Daniel Ubiles. All items from previous visit corrected except the following:
1) Panels still secure so hose bibs not accessible. Received video of access panel in place so both hose bibs now accessible in restrooms.
2) Light closest to pump room not secure to wall - gap >1/2". Pool builder secured to wall by applying pool putty around light. Recommend permanent repair. If light needs to be changed, will cause damage to the light/plaster when removed.
Construction final passed. Holds released in system.
Permit issued for no night swimming. The State permit should be available online by end of business 9/26. Local permit will be dropped off following week.
Permit Restriction: Pump required at 3450 RPM - or - Flow meter must remain operable with flow at 109 gpm to 138 gpm to meet turnover and flow restriction of the suction pipes.
Hayward TristarXL HCP3020 VSP, 2.7 THP pump with (2) Aquastar 2017 WAV12WRxxx drain covers. EQ lines plugged in skimmer. 4” side port that T’s to 3” line back to pump room.
Note: Plaster cracking on steps in multiple locations. May require repair in future if worsens.
Max Depth 4 ft.; Pool Width 30 ft.; Rope Length 45 ft.
Report emailed to GC/pool contractor and CPO.
bcaldwell@bainbridgere.com; Marsha Muller
; Brianna
; dubiles@bainbridgere.com; bainbridgemallardcreek@bainbridgere.com
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BAINBRIDGE MALLARD CREEK” or State ID 2060530824). Inspection type (routine vs. follow-up) is not published in the county's data.