Oct 8, 2026 4 demerits · 1 violation
Inspector comments: Inspection completed with Banks Parmley. Banks is the new CPO for the property. His CPO number NC* 0909250121.
Permit condition - Pool flow must be at least 31 GPM and cannot exceed 98 GPM for filter limitation. Flow meter must remain operational.
Intent to suspend permit issued for failure to record main drain safety checks daily. Correct within 30 days or the permit may be suspended.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Observed main drain safety recordings not being noted daily in log book. Intent to suspend permit issued. Correct within 30 days.
Apr 1, 2026 8 demerits · 2 violations
Inspector comments: Permit Restriction: Pool flow must be at least 31gpm and cannot exceed 98gpm for filter limitation. Flow meter must remain operational.
POOL IS NOT APPROVED FOR NIGHT SWIMMING
MAIN DRAIN COVERS EXPIRES 9/6/2030
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed one deck chair too close to the pool. Chair was moved. -CDI.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
.2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. Observed the automatic feeder not to shut off when flow stops. The feeder must be corrected. I.T.S. Issued, expires 5/1/2026. Failure to correct the item by the deadline may result in the closure of the pool.
Dec 12, 2025 0 demerits · 0 violations
Inspector comments: Pool permit approved.
Permit Restriction: Pool flow must be at least 31gpm and cannot exceed 98gpm for filter limitation. Flow meter must remain operational.
Note: Doors to amenity space do not meet the requirement of self-closing, self-latching. Parts for doors are on order and will be self-closing self-latching.
Permit will not be issued on 6/1/26 if doors are not corrected.
No violations were recorded for this inspection.