20demerits

LAKEHOUSE ON WYLIE, THE

11027 MOONBUG CT, Charlotte, NC 28278
Year-Round Swimming Pool · NC permit/State ID 2060530837
Latest result20 demerits
Last inspectedSep 15, 2026
Inspections on record2
On record sinceApr 17, 2026

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01020 Apr 17, 2026: 2Sep 15, 2026: 20
Apr 17, 2026Lower is betterSep 15, 2026

Inspections & violations

Sep 15, 2026 20 demerits · 5 violations
Inspector comments: Conducted inspection with CPO Rasaf. Intent to suspend issued for records and flow meter. Items must be corrected within 30 days or immediate suspension may be issued. Call EHS Devon when items are corrected. 7049981122 NOTES: 1) Flow meter must remain operable. Flow shall be maintained at 117 gpm to 196 gpm to meet turnover and flow restriction of the filters. No flow restriction on feature pump. 2)Pool is not approved for salt as primary chlorination. Const. Date: 1/5/2024 Rope Length: 45' Night Swim?: NO
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Inconsistent records for months. Ensure consistently daily and weekly records. Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope too short and falling apart. Operator replaced with new rope at approved 45’ length. No permit action.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Solid barriers that do not have openings shall contain no indentations or protrusions (greater than 1/2") except for normal construction tolerance . Handles on outside of gates protrude more than 2in and are 38 inches high creating a foothold. Operator removed handles to correct foothold. No permit action.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep the flow meter operational. Flow meter not operational. Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Tools and chemicals blocking equipment access. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals in pump room. Move to designated chemical storage room.

View this inspection on the county portal ›

Apr 17, 2026 2 demerits · 1 violation
Inspector comments: Maintain ring buoy rope at 45’. PERMIT RESTRICTION: Flow meter must be operational. Flow shall be maintained between 117gpm and 196gpm to meet turnover and restriction of filters.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(l) Provide toilet paper and dispensers in restrooms.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “LAKEHOUSE ON WYLIE, THE” or State ID 2060530837). Inspection type (routine vs. follow-up) is not published in the county's data.