20demerits
SEVENTEEN HUNDRED, THE
1755 LOMBARDY CR, Charlotte, NC 28203
Year-Round Swimming Pool · NC permit/State ID 2060530854
Latest result20 demerits
Last inspectedOct 22, 2026
Inspections on record2
On record sinceApr 13, 2026
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 13, 2026Lower is betterOct 22, 2026
Inspections & violations
Oct 22, 2026 20 demerits · 4 violations
Inspector comments: No night swimming. Heater off at time of inspection.
Permit restriction: Pressure and vacuum gauges must remain operable. Pump flow must be at least 50 GPM for turnover and cannot exceed 300 GPM for number of returns. Suction hazard at 525 gpm.
VFD required at 60 hz
Inspection with Mercier Loupesi
Discussed possibility of removing fencing and gate at front of pool, so door onto pool deck from lounge area would be barrier, including door across bridge and into another building. If this change is made, all doors would need to meet compliance of self-closing, self-latching or alarmed. Submit general in-field plan review application to Health Dept. If this change is going to be made for approval. Mainline 980-314-1620
#3 · Water quality: pool water pH −6
PH 8.0 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8. Operator adjusted to 7.4 Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook and ring buoy behind cabana and planters, not easily accessible. .2530(a) Lifesaving equipment should be conspicuously and conveniently located. Operator moved to outer edge of pool and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door onto pool deck not latching at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or self-closing and child protected by audible alarm. Operator adjusted to self-close and latch/lock. Corrected.
*permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs and furniture within 6 ft of pool.
.2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. Operator moved furniture and corrected.
Apr 13, 2026 0 demerits · 0 violations
Inspector comments: Inspection completed with Mercier Loupesi and Bryson Whisnant present.
Permit conditions - pressure and vacuum gauges must remain in place and functioning. VFD required at 60 hz for measurement. Calculated TDH shall not be less than 65’ so not to exceed 300gpm on curve. Flow range required at 50 GPM to 300GPM to meet turnover and flow restriction of number of returns. Flow greater than 525 gpm exceeds the main drains. Suction hazard.
Note- some rust on handrails that lead into pool deck where railing meets water.
Fence and gate near clubhouse area with gap underneath at 4 inches. The clubhouse door and outer building perimeter will be considered as the pool barrier.
No violations were recorded for this inspection.