8demerits
HEARTWOOD AT VERMILLION
16035 LIKELY LN, Huntersville, NC 28078
Year-Round Swimming Pool · NC permit/State ID 2060530873
Latest result8 demerits
Last inspectedSep 28, 2026
Inspections on record2
On record sinceAug 20, 2026
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Aug 20, 2026Lower is betterSep 28, 2026
Inspections & violations
Sep 28, 2026 8 demerits · 2 violations
Inspector comments: Intent to Suspend issued for:
.2528 - eliminate horizontal on building at GFCI.
Notes - 911 operator faint. Recommend turning up phone so clearly audible. 911 operator stated EHS could clearly be heard.
Corner tie in at sun shelf with offset. Ground down during original construction. Monitor. Repair work being done next to pool area and may cause shifting of decking. Ensure no offsets >1/2".
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No cyanuric acid and total alkalinity not recorded weekly. Some weekends missing records. Ensure daily record keeping for chlorine, pH and main drain checks. Ensure weekly record keeping for total alkalinity. Permit action will be taken if records not maintained.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
GFCI outlet on building outside of clubhouse entrance next to barrier. Provide angle overtop outlet to eliminate horizontal. Intent to Suspend issued.
Note - mulch under barrier at backside by drainage area may present issue in future with wash-out. Ensure 2" under barrier in all locations.
Aug 20, 2026 12 demerits · 4 violations
Inspector comments: Construction final and pre-permit inspection conducted with Mason Garrett, Hot Springs Pools, Rick Pidgeon, Embrey, and CPO Eric Mack.
911 had difficulty hearing me. Recommend having Kings III check the emergency call box.
Rocks and mulch built up above grade to eliminate gaps under the fencing, especially around landscape drain. Maintain fencing with no gaps > 2” under the fence and at least 48” high from the outside approach.
Fencing at the top of the ramp where retaining wall meets fencing is approved.
Fencing not completed at time of inspection. Left at 12:00 PM, returned at 2:10 PM and verified top of retaining wall now fenced off and additional metal bar added to eliminate gaps > 2” under the fence to the left of the fireplace.
Filtration pump - Pentair Intelliflo3 VSF 011075 - (2) Hayward WG1032BHF2 VGBA 2017
Feature pump - Pentair Superflo VST 342002 2.2 THP - Pulls through filtration main drains
Pool max depth 4ft 6in - Pool width 35 ft 6 in - Rope length 50 ft
Permit issued with the following conditions
No Night Swimming
Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 days for your records.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place on log sheet for cyanuric acid or main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance activities. - Corrected. Left copy of state log sheet.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder missing an endcap. .2521 Install ladders per manufacturer instructions. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gaps > 2” under the fence in places. .2528(a) Maintain 2" or less under fence and/or gate. - Corrected.
Brick wall by back gate and areas of fencing < 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Corrected.
Fence section at back corner < 48” high. Discussed installing a wing on the fencing to block access to the top of the retaining wall. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Corrected
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bags of dry chemicals on the floor of the chemical storage room. .2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies. - Corrected.